Analyzer
Systems for Industrial and Medical Use |
|
|
Analyzer systems, CEMS, panel building, sampling systems and
integration for the industrial gas industry, chemical plants,
refineries and Greenhouse Gases.
Siemens, Serovmex, Delta-F,
Teledyne, General Monitors, Ametek, Rosemount and many others.
24 Hr service in western New York.
Landfill Gas
Biomass Power Generation Plants
Oxygen Analyzers
SOx, NOx, O2, N2, THC, CO2, CO, CH4, Helium, Rare Gases, N2O, Trace
Argon
analyzer characterization, validation, validation to 21
CFR 210/211 and USP section 1226 as well as ASTM D 3764. On-site
validation for medical products in accordance with CGA P-8.2.
Continuous
Emissions Monitoring Systems (CEMS)
data sheet.
Landfill
Gas Analyzer Systems datasheet.
|
|
|
|
|
|
|
 |
 |
|
|
|
|
|
|
|
|
|
 |
|
|
|
|
| |
|
|
|
|
|
Landfill Gas
Continuous Monitoring Systems
Continuous monitoring of landfill gases for LFG to
energy or flare applications.
Methane (CH4), carbon dioxide (CO2),
hydrogen sulfide (H2S)
and oxygen (O2). Dry basis
sample system ensures reliable and long lasting
operation. Analyzer has an auto
calibration feature and digital display. The system
is safety instrumented. SCADA data
logger records concentration, process flow and
alarms every 15 minutes to meet
reporting requirements. Installs indoors or
outdoors. A sample pump is required for
flares or sample pressures less than 20 psig.
Model Components
Measured
LFG2001 Methane (CH4)
LFG2002 Methane (CH4),
Oxygen (O2)
LFG2003 Methane (CH4), Carbon
Dioxide (CO2), Oxygen (O2)
LFG2004 CH4, CO2, O2, Hydrogen
Sulfide (H2S)
LFGSCADA Logs CH4,
CO2,
O2,
H2S,
Flow and Alarms |
 |
| |
|
|
|
|
| |
| |
|
|
|
|
|
Industrial Gas
Continuous Monitoring Systems
Continuous monitoring for fossil fuel, greenhouse
gas, or engine emissions including
methane (CH4), carbon dioxide (CO2), oxygen (O2),
nitric oxide (NO), carbon monoxide
(CO), refrigerant (R22), and ethylene (C2H4). Dry
basis sample system for reliability and
long life. NEMA 1, 4/12 cabinets.
Model Components
Measured
CMS11 CH4 or CO2 or NO or CO
or R22 or C2H4
CMS12 Any 2 IR Components
Above
CMS13 Any 2 IR Components and
Oxygen (O2) |
 |
| |
|
|
|
|
|
|
| |
|
|
|
|
|
Continuous Emission Monitoring Systems
Continuous monitoring of combustion sources for
carbon monoxide (CO) and oxygen
(O2).
Dry basis sample system for reliability and long
life. Redundant systems ensure
ultra-high on stream factor. Automatic calibration
routine and alarming. Installs in a
shelter or indoors.
Model Function
CEMS121 Single Channel CO and
O2
CEMS122 Redundant CO and O2
channels
|
 |
| |
|
|
|
|
|
|
| |
|
|
|
|
|
Gas
Sample Pump Systems
Sample pump systems for landfill gas and industrial
continuous monitoring systems
where the sample pressure must be raised to the
required operating pressure of analyzer
systems. Either stainless steel bellows type or
teflon diaphragm style. Produces 15 SCFH
at 15 psig. Requires 120 VAC 60 Hz 1A power. Indoor
or outdoor operation.
Model Style
FSPSSB Stainless Steel Bellows
FSPTD Teflon Diaphragm w/316 SS Body
|
 |
| |
|
|
|
|
|
 |
 |
 |
 |
|
 |
 |
 |
|
|
|
 |
|
|
|
|
|
|
|
|
|